Product Description

Jelight / UVP Blak-Ray B-100YP High Intensity Yellow-Filter Wafer/PCB Inspection Lamp

is a high intensity 100-watt wafer inspection lamp designed for semiconductor fabrication, cleanroom inspection, and fine surface particle detection. Originally part of the UVP Blak-Ray B-100 high intensity lamp family and now supported through Jelight, the B-100YP uses a yellow filter to block wavelengths shorter than 500 nm and produce strong mercury emission lines at 543, 574, and 576 nm. This high-contrast output helps make small particles and surface contamination easier to see while reducing exposure in wavelength regions commonly absorbed by photoresist materials.

The B-100YP combines a Cool-Touch plastic lamp housing, transformer ballast base, 360-degree rotating lamp head, and removable handheld design for flexible benchtop or inspection-station use. It is available in 115 V and 230 V configurations.

Applications

Semiconductor Wafer Inspection

Used for high-contrast visual inspection of wafers and fine surface particles in semiconductor fabrication and process-control environments.

  • Wafer surface particle detection
  • Cleanroom inspection stations
  • Photoresist-sensitive inspection workflows
  • Process engineering and yield-improvement checks

Electronics and Precision Manufacturing

The B-100YP is useful where strong contrast is required to identify dust, residues, surface contamination, or fine defects on components and materials.

  • Electronic component inspection
  • Fine surface contamination review
  • Production quality control
  • Incoming material inspection

Laboratory and Materials Inspection

Laboratories and technical service teams can use the lamp as a high-intensity inspection source where yellow-filtered, high-contrast illumination is preferred over conventional longwave UV fluorescence viewing.

  • Materials inspection
  • Surface cleanliness review
  • Technical troubleshooting
  • Research and development inspection tasks

Features

  • Yellow-filtered high-contrast output helps make fine particles and surface contamination easier to distinguish.
  • Designed for semiconductor wafer inspection, including applications where photoresist exposure below 450 nm is a concern.
  • Particles down to 10 microns are routinely visible under appropriate inspection conditions.
  • Cool-Touch plastic housing allows safer handling of the lamp head during operation compared with hot aluminum lamp-head designs.
  • Lamp head rotates 360 degrees when mounted in the transformer base for hands-free bench positioning.
  • Removable lamp head allows handheld inspection when the application requires mobility.
  • Transformer ballast base supports stable operation and provides a convenient holder for storage and hands-free use.
  • Optional visor, funnel, and exposure box help control stray light and focus the inspection area.

Specifications

Product series Jelight / UVP Blak-Ray B-100 High Intensity Lamps
Model B-100YP
Product type High intensity yellow-filter wafer inspection lamp
Lamp power 100 watts
Filter type Yellow filter
Filtered output characteristics Blocks wavelengths shorter than 500 nm; produces strong mercury lines at 543, 574, and 576 nm
Particle visibility Particles down to 10 microns are routinely visible under appropriate inspection conditions
Housing Cool-Touch heat-resistant plastic lamp head
Lamp head movement 360-degree rotation when mounted in transformer base
Cord length 8 ft (2.44 m) primary and secondary line cords
Lamp head dimensions 9.75 in. L x 6 in. diameter (248 x 152 mm)
Weight 12.5 lb (5.67 kg)
Standard 115V model SKU number JLT 95-0127-03
Optional 230V model SKU number JLT 95-0127-04
Warm-up behavior Starts immediately when cool; allow approximately 5 minutes to reach full brilliance
Restart behavior Restart delay is typically 4 to 8 minutes after the mercury vapor arc is extinguished

Optional Accessories

Part Number Description
34-0054-01 Replacement spot bulb
38-0168-02 Bezel and yellow filter assembly for B-100YP
19-0125-01 Lamp visor for B-100YP Cool-Touch models
19-0126-01 Lamp funnel for directing light to a specific inspection area
76-0055-01 Exposure box for close-range sample exposure in a semi-enclosed area
UVC-503 UV safety goggles recommended for reducing blue haze and protecting eyes during UV inspection work

Documentation

  • UVP/ Jelight Blak-Ray B-100 Series Operating Instructions [PDF Download]

FAQs

What is the B-100YP used for?

The B-100YP is used for high-contrast wafer inspection and fine surface particle detection, especially in semiconductor fabrication and cleanroom quality-control environments.

How is the B-100YP different from the B-100Y?

Both models use a yellow filter for high-contrast particle detection. The B-100Y uses a scratch-resistant powder-painted aluminum housing, while the B-100YP uses a Cool-Touch heat-resistant plastic housing.

Does the B-100YP operate like a standard 365 nm fluorescence inspection lamp?

No. The B-100YP is a yellow-filter model designed for high-contrast wafer and particle inspection. Its yellow filter blocks wavelengths shorter than 500 nm and produces strong mercury lines at 543, 574, and 576 nm. For conventional 365 nm longwave UV fluorescence inspection, review B-100AP or other longwave UV models.

Can the B-100YP be used hands-free?

Yes. The lamp head fits into the transformer base and rotates 360 degrees for hands-free positioning. The lamp head can also be removed from the base for handheld inspection.

What replacement parts are available for the B-100YP?

Common replacement and accessory items include the 34-0054-01 spot bulb, 38-0168-02 bezel and yellow filter assembly, 19-0125-01 lamp visor, 19-0126-01 lamp funnel, and 76-0055-01 exposure box.

What safety precautions are required?

Use appropriate UV-rated eye and skin protection, avoid direct exposure, unplug the lamp before servicing, allow the bulb to cool before handling, and replace cracked filter glass immediately. The bulb contains mercury and must be handled and disposed of according to applicable local regulations if broken.

Warranty

Manufacturer documentation states that B-100 Series products are guaranteed to be free of defects in materials, workmanship, and manufacture for one year from the date of purchase. Consumable and disposable parts, including tubes and filters, are guaranteed to be free from defects in manufacture and materials for 90 days from the date of purchase. Warranty coverage does not apply to damage caused by accident, negligence, alteration, abuse, misuse, or service outside the operating instructions.

For warranty questions, replacement parts, or service support, contact Labgear USA before returning any product.

Ordering

Order the Jelight / UVP Blak-Ray B-100YP by voltage: select for 115V (JLT 95-0127-03) or  230V (95-0127-04). For semiconductor inspection stations, cleanroom QC, or replacement of an existing UVP B-100YP lamp, verify voltage, plug requirements, and any needed accessories before checkout.