Loading... Please wait...
is a high intensity 100-watt wafer inspection lamp designed for semiconductor fabrication, cleanroom inspection, and fine surface particle detection. Originally part of the UVP Blak-Ray B-100 high intensity lamp family and now supported through Jelight, the B-100YP uses a yellow filter to block wavelengths shorter than 500 nm and produce strong mercury emission lines at 543, 574, and 576 nm. This high-contrast output helps make small particles and surface contamination easier to see while reducing exposure in wavelength regions commonly absorbed by photoresist materials.
The B-100YP combines a Cool-Touch plastic lamp housing, transformer ballast base, 360-degree rotating lamp head, and removable handheld design for flexible benchtop or inspection-station use. It is available in 115 V and 230 V configurations.
Used for high-contrast visual inspection of wafers and fine surface particles in semiconductor fabrication and process-control environments.
The B-100YP is useful where strong contrast is required to identify dust, residues, surface contamination, or fine defects on components and materials.
Laboratories and technical service teams can use the lamp as a high-intensity inspection source where yellow-filtered, high-contrast illumination is preferred over conventional longwave UV fluorescence viewing.
| Product series | Jelight / UVP Blak-Ray B-100 High Intensity Lamps |
| Model | B-100YP |
| Product type | High intensity yellow-filter wafer inspection lamp |
| Lamp power | 100 watts |
| Filter type | Yellow filter |
| Filtered output characteristics | Blocks wavelengths shorter than 500 nm; produces strong mercury lines at 543, 574, and 576 nm |
| Particle visibility | Particles down to 10 microns are routinely visible under appropriate inspection conditions |
| Housing | Cool-Touch heat-resistant plastic lamp head |
| Lamp head movement | 360-degree rotation when mounted in transformer base |
| Cord length | 8 ft (2.44 m) primary and secondary line cords |
| Lamp head dimensions | 9.75 in. L x 6 in. diameter (248 x 152 mm) |
| Weight | 12.5 lb (5.67 kg) |
| Standard 115V model SKU number | JLT 95-0127-03 |
| Optional 230V model SKU number | JLT 95-0127-04 |
| Warm-up behavior | Starts immediately when cool; allow approximately 5 minutes to reach full brilliance |
| Restart behavior | Restart delay is typically 4 to 8 minutes after the mercury vapor arc is extinguished |
| Part Number | Description |
| 34-0054-01 | Replacement spot bulb |
| 38-0168-02 | Bezel and yellow filter assembly for B-100YP |
| 19-0125-01 | Lamp visor for B-100YP Cool-Touch models |
| 19-0126-01 | Lamp funnel for directing light to a specific inspection area |
| 76-0055-01 | Exposure box for close-range sample exposure in a semi-enclosed area |
| UVC-503 | UV safety goggles recommended for reducing blue haze and protecting eyes during UV inspection work |
The B-100YP is used for high-contrast wafer inspection and fine surface particle detection, especially in semiconductor fabrication and cleanroom quality-control environments.
Both models use a yellow filter for high-contrast particle detection. The B-100Y uses a scratch-resistant powder-painted aluminum housing, while the B-100YP uses a Cool-Touch heat-resistant plastic housing.
No. The B-100YP is a yellow-filter model designed for high-contrast wafer and particle inspection. Its yellow filter blocks wavelengths shorter than 500 nm and produces strong mercury lines at 543, 574, and 576 nm. For conventional 365 nm longwave UV fluorescence inspection, review B-100AP or other longwave UV models.
Yes. The lamp head fits into the transformer base and rotates 360 degrees for hands-free positioning. The lamp head can also be removed from the base for handheld inspection.
Common replacement and accessory items include the 34-0054-01 spot bulb, 38-0168-02 bezel and yellow filter assembly, 19-0125-01 lamp visor, 19-0126-01 lamp funnel, and 76-0055-01 exposure box.
Use appropriate UV-rated eye and skin protection, avoid direct exposure, unplug the lamp before servicing, allow the bulb to cool before handling, and replace cracked filter glass immediately. The bulb contains mercury and must be handled and disposed of according to applicable local regulations if broken.
Manufacturer documentation states that B-100 Series products are guaranteed to be free of defects in materials, workmanship, and manufacture for one year from the date of purchase. Consumable and disposable parts, including tubes and filters, are guaranteed to be free from defects in manufacture and materials for 90 days from the date of purchase. Warranty coverage does not apply to damage caused by accident, negligence, alteration, abuse, misuse, or service outside the operating instructions.
For warranty questions, replacement parts, or service support, contact Labgear USA before returning any product.
Order the Jelight / UVP Blak-Ray B-100YP by voltage: select for 115V (JLT 95-0127-03) or 230V (95-0127-04). For semiconductor inspection stations, cleanroom QC, or replacement of an existing UVP B-100YP lamp, verify voltage, plug requirements, and any needed accessories before checkout.
Add to Cart for standard ordering, or contact Labgear USA for help confirming configuration, replacement parts, documentation, and availability.
Choose a currency below to display product prices in the selected currency.
US Dollar
EURO - EUROPEAN UNION
JPY -JAPAN YEN
CAD - CANADA
INR - INDIA
CNY - CHINA
MXN - MEXICO
GBP - GREAT BRITAIN
SGD - SINGAPORE
KRW - SOUTH KOREAN REPUBLIC
AUD - AUSTRALIA
SAR - SAUDI ARABIA
ZAR - SOUTH AFRICAs
CHF - SWITZERLAND
ARA - ARGENTINA
BRL - BRAZIL
CLP - CHILE
COP - COLOMBIA
DKK - DENMARK
IDR - INDONESIA
NOK - NORWAY
NZD - NEW ZEALAND
PHP - PHILIPPINES
PLN - POLAND
SEK - SWEDEN
TWD - TAIWAN
UAH - UKRAINE
THB - THAILAND
MYR - MALAYSIAN RINGGIT
AED - UNITED ARAB EMIRATES
BGN - BULGARIA
HUF - HUNGARY
CZK - CZECH REPUBLIC
ILS - ISRAEL
EGP - EGYPT
TRY - TURKEY
RON - ROMANIA
KES - KENYA
PKR - PAKISTAN
IQD - IRAQ
KWD - KUWAIT
VND - VIET NAM
JMD - JAMAICA
DOP - DOMINICAN REPUBLIC
JOD - JORDAN
PEN - PERU