is ideal for operation of 150 watt to 300 Watt Short-Arc Xenon Lamps. The Ushio SmartArc HBX 300 is a compact, microprocessor-controlled electronic xenon lamp ballast for selected 150 W through 300 W DC short-arc lamps. Designed for scientific, medical, solar-simulation, and specialty optical equipment, it combines selectable lamp power, power-factor-corrected wide-range AC input, regulated digital power management, and integrated cooling in one OEM power module. The ballast maintains stable electrical output as lamp voltage changes over operating life, helping preserve repeatable light output while providing end-of-life monitoring and protective shutdown.
Compared with a traditional magnetic ballast, the HBX 300 provides a smaller integration footprint, broader input-voltage compatibility, electronic power regulation, remote-control capability, and multiple protection functions. It is intended for installation inside properly engineered equipment with a compatible external ignitor, lamp enclosure, interlocks, wiring, and thermal management. Confirm the exact lamp operating point, ignitor configuration, interface revision, and final-system safety requirements before installation.
| Parameter | Specification | Integration Notes |
|---|---|---|
| Brand / model | USHIO SmartArc HBX 300 | Electronic power supply / ballast for selected DC short-arc lamps |
| Item number | 5001597 | Confirm current production revision when ordering |
| Lamp power settings | 150, 185, 200, 250, and 300 W; output accuracy +/-2% | Power is presettable by DIL / 16-step switch; summary literature also describes an 180 W class |
| Lamp output voltage | 10-29 VDC; +/-5% depending on selected lamp | Verify the operating voltage of the exact lamp |
| Maximum lamp current | 22 A maximum | Depends on lamp selection and programmed power |
| Input voltage | 90-264 VAC operating range; 100-240 VAC nominal | Power-factor-corrected wide-range input |
| Line frequency | 47-63 Hz; 50/60 Hz nominal | For common worldwide mains frequencies |
| System wattage | 150-350 W | Depends on selected lamp and operating point |
| Input current | 0.6-1.4 A in the detailed HBX 300 electrical table; a separate HBX180/300 summary lists 4.5 A maximum | Confirm maximum current at the intended low-line input condition |
| Power factor | 0.92-1.0; 1.0 nominal | PFC input stage |
| Efficiency | 0.8-0.9; 0.83 nominal | Thermal design must account for conversion losses |
| Ignition voltage | +/-14 kV peak nominal; +/-12 to +/-16 kV with ZG20XE ignitor | Load capacitance less than 20 pF |
| Ignition time | 1.0 second nominal; 0.9-1.1 seconds | Automatic restart counter: 5 attempts |
| Open-circuit voltage | 110 V nominal; 105-115 V | High-voltage precautions apply |
| Lamp End-of-life Shutdown Voltage | 30 V nominal; +/-2 V | Supports shutdown as lamp voltage rises with age |
| Auxiliary fan output | Regulated 24 VDC; 200 mA maximum total | Available only while the lamp is lit; output is not isolated from line input |
| Control functions | Remote on/off, analog dim input, lamp-lit status output | Confirm connector and isolation details for the current revision |
| Cooling | Integrated fan | Final assembly must be tested so the designated case test point does not exceed 176 degrees F (80 degrees C) |
| Operating temperature | 14 to 104 degrees F (-10 to 40 degrees C) | Nominal condition: 77 degrees F (25 degrees C) |
| Storage temperature | -4 to 140 degrees F (-20 to 60 degrees C) | Store in a dry, non-condensing environment |
| Humidity | 20%-95% RH, non-condensing | Avoid condensation and conductive contamination |
| Operating altitude | 0-10,000 ft (0-3,048 m) | High-voltage spacing and cooling remain system-design responsibilities |
| Thermal shutdown | 194 degrees F (90 degrees C) nominal; 185-203 degrees F (85-95 degrees C) | Internal heatsink temperature switch |
| Dimensions (LxWxH) | 7.09 x 4.02 x 1.69 in. (180 x 102 x 43 mm) | Allow space for connectors, airflow, wiring bend radius, and high-voltage clearances |
| Weight | 1.54 lb (0.7 kg) | Nominal module weight |
| Ballast lifetime | More than 25,000 hours under nominal operating conditions | Documented at 230 VAC with a 158 degrees F (70 degrees C) test-point temperature |
| Internal fuse | T 5 A / 250 V | Replace only with the same type and rating |
| Lamp-output connection | J1 positive and J2 negative; 0.248 x 0.031 in. (6.3 x 0.8 mm) Faston | External ignitor connection; lamp HV cable terminates by M3 screw |
| Safety spacing | Minimum 0.59 in. (15 mm) from lamp terminals to protective earth |
Lamp compatibility is not determined by wattage alone. Confirm rated current, operating voltage, ignition method, polarity, cable capacitance, cooling, mechanical fit, and optical-system requirements before ordering.
The HBX 300 is designed for selected DC short-arc lamps in the 150-300 W range. Product literature identifies OSRAM XBO 150, XBO 250, and XBO 300; USHIO UXL 150 and UXL 300 UXR-300BF, UXR-300ES; and selected 300 W xenon lamps from Luxtel, PerkinElmer, and Excelitas. Superior Quartz SX150 Series, SX200, SX250X Series, SX300.
Confirm the exact lamp's voltage, current, ignition, polarity, thermal, and mechanical requirements before use.
Yes. The technical documentation specifies connection to an external ZG20Xe-series ignitor, with asymmetric and symmetric versions shown. Select the ignitor to match the lamp and system architecture, and confirm whether it is included in the quoted package.
Yes. Input range is 90-264 VAC at 47-63 Hz, allowing integration into equipment designed for common 120 V and 230 V mains supplies. Ensure correctly rated wiring, grounding, fusing, connectors, and safety protection.
Yes. Product designs can utilize the remote on/off, analog dimming input for optical feedback, and a lamp-lit status output for added features and capability.
An electronic ballast such as the HBX 300 provides regulated power, compact size, wide-range AC input, power-factor correction, selectable output, monitoring, and remote-control functions that are generally not available in a basic magnetic ballast. The result is easier OEM integration and better control of lamp operating conditions, although the electronic module still requires an external ignitor and a properly engineered high-voltage lamp system.
The HBX 180 is an open-frame version for applications up to 210 W. The HBX 300 includes additional heat sinking from a housing and fan and supports lamp power up to 300 W. This page describes only the HBX 300, item 5001597.
Yes, when appropriately integrated, this product enables meeting requirements for medical applications and medical-safety evaluations, but the power supply is an OEM component rather than a complete certified medical device. The finished equipment must be evaluated for all applicable electrical, thermal, EMC, mechanical, and regulatory requirements.
For technical or warranty support, provide the HBX 300 item number 5001597, approximate date of order, serial number, lamp manufacturer and model, selected wattage, AC input voltage, ignitor model, operating hours, and a description of the fault. Do not service, reconnect, or test the ballast while energized; the lamp circuit can generate hazardous high voltage.
Before ordering, confirm the exact lamp model, rated wattage, operating voltage and current, required ignitor type, AC mains range, control-interface needs, cooling arrangement, connector requirements, and quantity. ScienceLighting can help review the electrical match and identify the appropriate ballast, ignitor, lamp, and connection components for your system.
Select the required configuration and click Add to Cart. For OEM quantities, replacement-system matching, or applications requiring documentation review, request a written quotation before purchase.
Choose a currency below to display product prices in the selected currency.
US Dollar
EURO - EUROPEAN UNION
JPY -JAPAN YEN
CAD - CANADA
INR - INDIA
CNY - CHINA
MXN - MEXICO
GBP - GREAT BRITAIN
SGD - SINGAPORE
KRW - SOUTH KOREAN REPUBLIC
AUD - AUSTRALIA
SAR - SAUDI ARABIA
ZAR - SOUTH AFRICAs
CHF - SWITZERLAND
ARA - ARGENTINA
BRL - BRAZIL
CLP - CHILE
COP - COLOMBIA
DKK - DENMARK
IDR - INDONESIA
NOK - NORWAY
NZD - NEW ZEALAND
PHP - PHILIPPINES
PLN - POLAND
SEK - SWEDEN
TWD - TAIWAN
UAH - UKRAINE
THB - THAILAND
MYR - MALAYSIAN RINGGIT
AED - UNITED ARAB EMIRATES
BGN - BULGARIA
HUF - HUNGARY
CZK - CZECH REPUBLIC
ILS - ISRAEL
EGP - EGYPT
TRY - TURKEY
RON - ROMANIA
KES - KENYA
PKR - PAKISTAN
IQD - IRAQ
KWD - KUWAIT
VND - VIET NAM
JMD - JAMAICA
DOP - DOMINICAN REPUBLIC
JOD - JORDAN
PEN - PERU