is a self-powered analog UV intensity meter designed for measuring longwave ultraviolet sources from 300 to 400 nm, with peak sensitivity at approximately 365 nm. Its remote photovoltaic sensor and dual measurement scales make it well suited for UV lamp monitoring, fluorescence applications, quality control, comparative testing, and routine verification of UV-A sources.
The J-221 provides direct measurement of longwave ultraviolet intensity for routine monitoring of fluorescent UV-A lamps, blacklights, inspection lamps, and other sources operating within the 300–400 nm response range.
With peak sensitivity near 365 nm, the meter is well suited for checking UV-A sources used in fluorescence inspection, non-destructive testing, leak detection, laboratory examination, and related inspection processes.
The J-221 can be used to monitor lamp output over time, compare UV sources, identify declining lamp intensity, and support routine quality-control procedures where repeatable UV-A exposure is important.
The J-221 can be used with 365 nm line sources such as Blak-Ray B-100 Series UV lamps. For these sources, Jelight/UVP documentation specifies multiplying the displayed reading by 0.74 to obtain the corrected irradiance value.
| Meter Type | Analog photovoltaic UV intensity meter |
| Spectral Response | 300–400 nm |
| Peak Sensitivity | Approximately 365 nm |
| A Scale | 0–1,200 µW/cm² |
| B Scale | 1,000–6,000 µW/cm² |
| Minimum Detector Limit | 20 µW/cm² |
| Detector Linearity Tolerance | ±10% |
| Short-Term Repeatability | Better than ±1% under isothermal conditions |
| Sensor Cord Length | 1.2 m (4 ft) |
| Power Requirements | Self-powered photovoltaic sensor; no batteries required |
| Dimensions | 76 × 76 × 76 mm (3 × 3 × 3 in.) |
| Weight | 0.25 kg (0.56 lb / 9 oz) |
| Calibration | NIST-traceable calibration |
| Recommended Recalibration Interval | Every 6 months |
No. The J-221 uses a photovoltaic detector and is self-powered, eliminating the need for batteries or an external electrical power supply during measurement.
Yes. When measuring a 365 nm line source such as a Blak-Ray B-100 Series lamp, Jelight documentation specifies multiplying the displayed J-221 reading by 0.74 to obtain the corrected irradiance value.
The J-221 is calibrated for longwave phosphor-coated UV lamps. A concentrated 365 nm mercury line source produces a different detector response, causing the meter to read higher than the actual irradiance unless the specified correction factor is applied.
Yes. Jelight provides individually serialized UV meters and sensors with calibration traceability to NIST standards.
The Jelight J-221 365 nm Longwave UV Intensity Meter is warranted against defects in materials and workmanship under normal use and service. Please inspect all protective equipment before each use. For warranty assistance, replacement parts, product support, or application guidance, contact ScienceLighting technical support. Warranty valid for 12 months.
Have additional questions? Contact ScienceLighting at (650) 961-9031 or sales@sciencelighting.com.
Choose a currency below to display product prices in the selected currency.
US Dollar
EURO - EUROPEAN UNION
JPY -JAPAN YEN
CAD - CANADA
INR - INDIA
CNY - CHINA
MXN - MEXICO
GBP - GREAT BRITAIN
SGD - SINGAPORE
KRW - SOUTH KOREAN REPUBLIC
AUD - AUSTRALIA
SAR - SAUDI ARABIA
ZAR - SOUTH AFRICAs
CHF - SWITZERLAND
ARA - ARGENTINA
BRL - BRAZIL
CLP - CHILE
COP - COLOMBIA
DKK - DENMARK
IDR - INDONESIA
NOK - NORWAY
NZD - NEW ZEALAND
PHP - PHILIPPINES
PLN - POLAND
SEK - SWEDEN
TWD - TAIWAN
UAH - UKRAINE
THB - THAILAND
MYR - MALAYSIAN RINGGIT
AED - UNITED ARAB EMIRATES
BGN - BULGARIA
HUF - HUNGARY
CZK - CZECH REPUBLIC
ILS - ISRAEL
EGP - EGYPT
TRY - TURKEY
RON - ROMANIA
KES - KENYA
PKR - PAKISTAN
IQD - IRAQ
KWD - KUWAIT
VND - VIET NAM
JMD - JAMAICA
DOP - DOMINICAN REPUBLIC
JOD - JORDAN
PEN - PERU