Loading... Please wait...is a microprocessor-controlled UV crosslinker designed for biomolecular research and controlled laboratory irradiation at 302 nm. Featuring six 8 W UV-B tubes and an integrated radiometer, it delivers programmable UV energy or timed exposures within an enclosed, safety-interlocked chamber.
Provides programmable 302 nm UV-B exposure for laboratory research involving UV-induced biological and molecular changes. Measured energy delivery supports repeatable irradiation conditions for experimental procedures.
Supports DNA and RNA immobilization on compatible membranes when 302 nm irradiation is specified by the laboratory protocol. Programmable UV exposure allows researchers to establish controlled crosslinking conditions for applicable membrane-based procedures.
Enables controlled irradiation of samples and materials responsive to midrange ultraviolet radiation. Suitable for wavelength-dependent photochemical research, fluorescence studies, and selected UV-curing experiments using appropriate protocols.
| Instrument Type | Benchtop UV Crosslinker |
| Primary UV Wavelength | 302 nm (UV-B / Midrange) |
| Lamp Configuration | Six 8 W UV-B Tubes |
| Exposure Modes | Preset or User-Defined UV Energy and Time |
| UV Energy Setting Range | 0.1–9,999.9 mJ/cm² |
| Time Setting Range | 000:01–999:59 (Manufacturer-Listed Setting Range) |
| Input Voltage | 115 V or 230 V AC, 50/60 Hz (Variant Dependent) |
| External Dimensions | 410 × 400 × 265 mm (16.1 × 15.7 × 10.4 in) |
| Internal Chamber Dimensions | 350 × 270 × 160 mm (13.8 × 10.6 × 6.3 in) |
| Operating Temperature | 15–35 °C (59–95 °F) |
| Operating Humidity | Up to 70% Relative Humidity, Non-Condensing |
| Weight | 6.8 kg (15 lb) |
| Part Number | Model | Input Voltage |
|---|---|---|
| 849-95-0615-03 | CL-3000M | 115 V |
| 849-95-0615-04 | CL-3000M | 230 V |
No, the CL-3000M operates at 302 nm UV-B and is not a direct substitute for the 254 nm CL-3000 in procedures requiring UV-C irradiation. Select the appropriate wavelength and validated exposure conditions for the intended application rather than assuming equivalent disinfection performance.
The manufacturer's operating manual identifies 120 mJ/cm² as a recommended dose for nucleic acid immobilization, but this setting should not be assumed optimal for every wavelength or membrane. Follow the membrane manufacturer's instructions and a validated 302 nm protocol to determine the appropriate exposure.
The CL-3000M uses six Jelight 34-0042-01 replacement tubes rated at 8 W and 302 nm. The manufacturer recommends replacing all six together, and recalibration is not required when installing compatible tubes of the same wavelength.
Yes, the CL-3000M can be converted to another supported wavelength by replacing all six UV tubes and recalibrating the instrument with the appropriate wavelength-specific calibration sensor. Simply installing different-wavelength tubes without recalibration does not ensure accurate UV energy measurements. Contact ScienceLighting for guidance on compatible replacement components and calibration requirements.
This product is covered by a 12-month warranty against defects in materials and workmanship. Inspect the product before use and contact ScienceLighting support if any defects or issues are identified.
Have additional questions? Contact ScienceLighting at (650) 961-9031 or sales@sciencelighting.com.
Choose a currency below to display product prices in the selected currency.
US Dollar
EURO - EUROPEAN UNION
JPY -JAPAN YEN
CAD - CANADA
INR - INDIA
CNY - CHINA
MXN - MEXICO
GBP - GREAT BRITAIN
SGD - SINGAPORE
KRW - SOUTH KOREAN REPUBLIC
AUD - AUSTRALIA
SAR - SAUDI ARABIA
ZAR - SOUTH AFRICAs
CHF - SWITZERLAND
ARA - ARGENTINA
BRL - BRAZIL
CLP - CHILE
COP - COLOMBIA
DKK - DENMARK
IDR - INDONESIA
NOK - NORWAY
NZD - NEW ZEALAND
PHP - PHILIPPINES
PLN - POLAND
SEK - SWEDEN
TWD - TAIWAN
UAH - UKRAINE
THB - THAILAND
MYR - MALAYSIAN RINGGIT
AED - UNITED ARAB EMIRATES
BGN - BULGARIA
HUF - HUNGARY
CZK - CZECH REPUBLIC
ILS - ISRAEL
EGP - EGYPT
TRY - TURKEY
RON - ROMANIA
KES - KENYA
PKR - PAKISTAN
IQD - IRAQ
KWD - KUWAIT
VND - VIET NAM
JMD - JAMAICA
DOP - DOMINICAN REPUBLIC
JOD - JORDAN
PEN - PERU