is a 6 W replacement ultraviolet tube that emits longwave UV radiation at 365 nm. Designed for compatible Jelight Handheld, EL Series, Rechargeable, and legacy 3UV lamps, it restores UV-A output for laboratory inspection, fluorescence examination, and equipment maintenance.
Restores 365 nm UV excitation in compatible lamps used to examine fluorescent minerals, dyes, coatings, and other UV-responsive materials. The replacement tube supports continued longwave fluorescence inspection when the original tube loses output or requires replacement.
Provides replacement UV-A illumination for compatible laboratory lamps used in sample examination and analytical inspection. Suitable for equipment requiring a 6 W, 365 nm longwave UV light source.
Replaces worn or damaged 365 nm tubes in compatible Jelight Handheld, EL Series, Rechargeable, and legacy 3UV equipment. Proper tube replacement helps maintain the intended performance of the existing lamp assembly.
| Lamp Type | Longwave UV Fluorescent Tube |
| Primary UV Wavelength | 365 nm |
| UV Region | UV-A |
| Lamp Power | 6 W |
| Tube Style | T5 Linear |
| Base | G5 Miniature Bi-Pin |
| Nominal Overall Length | Approximately 228.6 mm (9.0 in) |
| Tube Diameter | Approximately 15.9 mm (0.625 in) |
The UVL-56 uses the 34-0034-01 as its 365 nm UV-A light source, while the UVGL-58 uses one alongside a separate 254 nm tube. The UVGL-55 instead requires the split-wavelength replacement tube 34-0015-01.
The UVL-16, UVLM-26, and UVLS-26 each require one 34-0034-01 tube, while the UVL-26 requires two. Other positions in multi-source models use the appropriate 254 nm, 302 nm, or white-light replacement tubes.
No, the 34-0016-01 is a separate blacklight-blue (BLB) tube specified for equipment such as the UVL-26P. Although both tubes produce nominal 365 nm UV-A radiation, they are not interchangeable replacements. The UVSL-26P uses the 34-0034-01 for its longwave position.
Disconnect the equipment from power and allow the tube to cool before replacement. Follow the equipment manual, handle the glass carefully, and ensure appropriate UV-protective eyewear, skin protection, and shielding are in place before operation. Avoid looking directly at an exposed UV source.
Handle used tubes as potentially mercury-containing fluorescent lamps and follow applicable recycling or hazardous-waste requirements. If a tube breaks, follow appropriate mercury-lamp cleanup procedures rather than treating the fragments as ordinary glass waste.
This product is covered by a 12-month warranty against defects in materials and workmanship. Inspect the product before use and contact ScienceLighting support if any defects or issues are identified.
Have additional questions? Contact ScienceLighting at (650) 961-9031 or sales@sciencelighting.com.
Choose a currency below to display product prices in the selected currency.
US Dollar
EURO - EUROPEAN UNION
JPY -JAPAN YEN
CAD - CANADA
INR - INDIA
CNY - CHINA
MXN - MEXICO
GBP - GREAT BRITAIN
SGD - SINGAPORE
KRW - SOUTH KOREAN REPUBLIC
AUD - AUSTRALIA
SAR - SAUDI ARABIA
ZAR - SOUTH AFRICAs
CHF - SWITZERLAND
ARA - ARGENTINA
BRL - BRAZIL
CLP - CHILE
COP - COLOMBIA
DKK - DENMARK
IDR - INDONESIA
NOK - NORWAY
NZD - NEW ZEALAND
PHP - PHILIPPINES
PLN - POLAND
SEK - SWEDEN
TWD - TAIWAN
UAH - UKRAINE
THB - THAILAND
MYR - MALAYSIAN RINGGIT
AED - UNITED ARAB EMIRATES
BGN - BULGARIA
HUF - HUNGARY
CZK - CZECH REPUBLIC
ILS - ISRAEL
EGP - EGYPT
TRY - TURKEY
RON - ROMANIA
KES - KENYA
PKR - PAKISTAN
IQD - IRAQ
KWD - KUWAIT
VND - VIET NAM
JMD - JAMAICA
DOP - DOMINICAN REPUBLIC
JOD - JORDAN
PEN - PERU