USHIO’s SMARTARC™ELDC 2.31 electronic power supply with digital power management and microprocessor controls, power factor correction, and comprehensive protection mechanisms in a compact and “intelligent” solution. Operates 100W to 200W DC short arc discharge lamps such as Emarc SMR200, HTL 38465, HXP R120 and others. (Call to verify compatibilty.)
Operates various EmArc® HTL and HXP R type DC short arc lamps in power ranges between 100W-200W and operating voltages between 36V-98V.
Output selections are adjustable in 6 steps via solder bridges (call for details).
Power factor corrected line input with built-in EMI filter.
Wide input voltage range: 90VAC to 264VAC.
Meets CE & FCC Part “A” standards.
Newly designed anti-aging and arc control circuit for high optical reliability over lamp lifetime.
Digital power management and microprocessor controlled with high output stability.
Output is short circuit protected.
Includes a 90ºC thermal shut-off feature.
Photo feedback terminal connection enables customer individualized lighting system regulation.
Auxiliary 24V/200mA output at two terminals for fan drive (available when the lamp is in operation).
UL1950, UL508, UL2601, CSA C22.2 Certification.
All values are valid at 25° ±5°C, unless otherwise noted.
Parameter | Nominal | Tolerance |
---|---|---|
Input Voltage AC (V) | 100 – 240 | 90 – 264 |
Input Voltage DC (V) | 100 – 300 | 90 – 340 |
System Wattage (W) | 200 | 100 – 200* |
Input Current (A) | — | 1 – 3 |
Line Frequency (Hz) | 50/60 | 47 – 63 |
Power Factor | 1.0 | >0.93 |
*Presettable in 6 steps. Continuous variable from preset to 200W by optocoupler.
Parameter | Nominal | Tolerance |
---|---|---|
Lamp Voltage (V) | 60 | 36 – 95 |
Lamp Wattage (W) | 100 – 200 | — |
Lamp Current (A) | — | I Max = 5.7 |
Cut-Off Voltage, End-Life (V) | 98 | 99 – 101 |
Open Circuit Voltage (V) | 240 | 230 – 260 |
Parameter | Nominal | Tolerance | Remarks |
---|---|---|---|
Ignition Voltage (kV peak) | ±14 | ±12 – ±16 | Load Capacity <20pF |
Ignition Time (sec.) | 1 | 0.9 – 1.1 | |
Automatic Restart Counter | 5 | — | Attempts |
Connector | Manufacturer / Type | Remarks / Header / Contacts |
---|---|---|
Ballast Mains Plug | ST101 3X AMP faston 2.8 x 0.8 | Single terminals |
Ballast Interface Plug | S102 JST/B4B-PH-K-S (grid 2mm) 4 pin | JST PHR4/SPH-002T-PO.5S |
Fan Connection Plug | STH103, STH104 JST/B2B-EH-A | For 24V fan 100mA (2.6W) max. Output capacity 200mA/25V±1V (Both terminals together) JST EHR2/SEH-001T-PO.6 |
Connection Ballast-Ignitor | ST105 AMP640445-2 (ELDC 2.3i) | AMP 770 849-2/770522-1 |
Ignitor HV-plug to Lamp | Housing: SMK/101CCT-09-01R | ZG 5L or built-in ignitor |
Lamp Cable | Tecnosil/AWG20 UL Style 3239, 20kVDC |
Connector | Pin | Signal | Description |
---|---|---|---|
Line Input ST101 | 1 | AC in -L- | AC wide range input voltage 90V-264VAC |
2 | AC in -N- | DC wide range input voltage 90V-340VDC | |
3 | PE | ||
Control Interface | 1 | input | Photo-feedback/Dimming 0-10mA (input) dim to preset level |
2 | output | Lamp Running 2mA, true if low (output) open collector | |
3 | GND | ||
4 | GND |
Nominal Efficiency: 0.88
Ambient Temperature: 15°C - 75°C
Max. Design Temperature at Test Point: 80°C
Switch Off Temperature: 90°C
Aux. Power: two 24V terminals for driving one or two fans. One is intended for the power supply and one for the lamp. The maximum total output current for both outputs is 200mA. Note that the output voltage is only available when the lamp is in operation.
Storage Temperature Range: -20°C – +50°C
Humidity Range: 20% – 95% non-condensing
Altitude (Operating): 0 ft. to 10,000 ft.
Safety and Performance Standards: CSA C22.2 No.60950 UL60950,UL508, UL2601 Certified (CB-Test and UL must be completed with the final product.)
Dimensions (L x W x H): 180 x 71 x 32 mm
Weight: 0.472 kg (1 lb)
HEAT SINK AND SAFETY: The heat sink is connected to line voltage. Do not touch or connect to PE!